Initial value change list
PARAMETERS
4
4.21 Initial value change list
Displays and sets the parameters changed from the initial value.
Operation Display
1. Screen at power-ON
The monitor display appears.
2. Press to choose the PU operation mode.
PU indicator is lit.
3. Press to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously
appears.)
4. Turn until appears.
5. Pressing changes to the initial value
change list screen.
* It may take several seconds
for creating the initial value
change list.
" "
flickers while creating the list.
6. Turning displays the parameter number
changed.
Press to read the present set value.
Turn and press to change the
setting
(
R
efer to step 6 and 7 on page 51.)
Flicker Parameter setting complete!!
Turn to read another parameter.
The display returns to after all
parameters are displayed.
7. Pressing in status returns to
the parameter setting mode.
Turning sets other parameters.
Pressing displays the change list again.
NOTE
Calibration parameters (C0 (Pr. 900) to C7 (Pr. 905)) are not displayed even when these are changed from the initial
settings.
Only simple mode parameter is displayed when simple mode is set (Pr. 160 = "9999" (initial value))
Pr. 160 is displayed independently of whether the setting value is changed or not.
When parameter setting is changed after creating the initial value change list, the setting will be reflected to the initial
value change list next time.
Parameters referred to
Pr. 160 Extended function display selection Refer to page 144
C0 (Pr. 900) FM terminal calibration Refer to page 123
C2(Pr. 902) to C7(Pr. 905) (Speed setting bias/gain parameter) Refer to page 135