![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/24/b249deaf-1fd7-4d91-a629-3b60b4c6e920/b249deaf-1fd7-4d91-a629-3b60b4c6e920-bgbb.png)
185
Communication operation and setting
4
PARAMETERS
[Drive unit status monitor]
∗ The signal is the initial setting. The description changes depending on the Pr. 190, Pr. 192 (output terminal function selection).
[Multi command (HF0)]
Sending data format from computer to drive unit
Reply data format from drive unit to computer (No data error detected)
∗1 Specify the data type of sending data (from computer to drive unit).
∗2 Specify the data type of reply data (from drive unit to computer).
∗3 Combination of data 1 and data 2 for sending
∗4 Combination of data 1 and data 2 for reply
∗5 Error code for sending data 1 is set in error code 1, and error code for sending data 2 is set in error code 2.
Mode error (HA), instruction code error (HB), data range error (HC) or no error (HF) is replied. (Refer to page 178 for more details of the error codes.)
Item
Instruction
Code
Bit
Length
Description Example
Drive unit
status
monitor
H7A 8 bits
b0: RUN (drive unit running (Variable))
∗
b1: Forward rotation (Fixed)
b2: Reverse rotation (Fixed)
b3: up-to-speed (Fixed)
b4: overload (Fixed)
b5: —
b6: speed detection (Fixed)
b7: ABC (fault (Variable)) ∗
Drive unit
status
monitor
(expansion)
H79 16 bits
b0: RUN (drive unit running (Variable)) ∗
b1: During forward rotation (Fixed)
b2: During reverse rotation (Fixed)
b3: up-to-speed (Fixed)
b4: overload (Fixed)
b5: —
b6: speed detection (Fixed)
b7: ABC (fault (Variable)) ∗
b8 to b14: —
b15: Fault occurrence
Format
Number of Characters
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A3
ENQ
Drive unit
station
number
Instruction
code
(HF0)
Waiting
time
Send
data
type
∗1
Receive
data
type
∗2
Data1
∗3
Data2
∗3
Sum
check
CR/LF
Format
Number of Characters
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
C1
STX
Drive unit
station
number
Send
data
type
∗1
Receive
data
type
∗2
Error
code 1
∗5
Error
code 2
∗5
Data1∗4
Data2
∗4
ETX
Sum
check
CR/LF
Data Type
Data 1
Data 2
Remarks
0
Run command
(extended)
Set speed (RAM)
Run command (expansion) is same as instruction code HF9
(Refer to page 184)
The unit of set speed (frequency) is always by four digits, even
when "0.01 to 9998" is set in Pr. 37 and "01" is set in instruction
code HFF.
1
Run command
(extended)
Set speed
(RAM,
EEPROM)
Data Type
Data 1
Data 2
Remarks
0
Drive unit status
monitor (extended)
Rotation speed
(Output frequency)
Drive unit status monitor (expansion) is same as instruction code
H79 (Refer to page 185)
Rotation speed (frequency) monitor is in 1 increments. (Numbers
after the decimal point are rounded.)
Replies the monitor item specified in instruction code HF3 for
special monitor.(Refer to page 183)
1
Drive unit status
monitor (extended)
Special monitor
00000010
b7 b0
[Example 1] H02... During forward rotation
[Example 2] H80... Stop at fault occurrence
10000000
b7 b0
00000010
b0
00000000
b15
[Example 1] H0002... During forward rotation
10000000
b0
10000000
b15
[Example 2] H8080... Stop at fault occurrence