Communication operation and setting
4
PARAMETERS
(6) Modbus registers
System environment variable
∗1 The communication parameter values are not cleared.
∗2 For write, set the data as a control input instruction.
For read, data is read as an drive unit operating status.
∗3 For write, set data as the operation mode setting.
For read, data is read as the operation mode status.
Register Definition Read/write Remarks
40002 Drive unit reset Write Any value can be written
40003 Parameter clear Write Set H965A as a written value.
40004 All parameter clear Write Set H99AA as a written value.
40006 Parameter clear ∗1 Write Set H5A96 as a written value.
40007 All parameter clear ∗1 Write Set HAA99 as a written value.
40009 Drive unit status/control input instruction ∗2 Read/write See below.
40010 Operation mode/drive unit setting ∗3 Read/write See below.
40014 Running speed (RAM value) Read/write
According to the Pr. 37 and Pr. 144 settings,
the selectable speed and frequency are in
0.01Hz increments.
40015 Running speed (EEPROM value) Write
<Drive unit status/control input instruction>
∗1 The signal is the initial setting. Definitions change according to the Pr. 180 to Pr. 182 (input terminal function selection) (refer to page 100).
Each assigned signal is valid or invalid depending on NET. (Refer to page 160)
∗2 The signal is the initial setting. Definitions change according to the Pr. 190, Pr. 192 (output terminal function selection) (refer to page106).
Bit
Definition
Control input instruction Drive unit status
0 Stop command (Fixed)
RUN (drive unit running ∗2
(Variable))
1
Forward rotation command
(Fixed)
During forward rotation (Fixed)
2
Reverse rotation command
(Fixed)
During reverse rotation (Fixed)
3
RH (high-speed operation
command ∗1 (Variable))
Up-to-speed (Fixed)
4
RM (middle-speed operation
command ∗1 (Variable))
Overload (Fixed)
5
RL (low-speed operation
command ∗1 (Variable))
0
6 0 Speed detection (Fixed)
7 Second function selection (Fixed) ABC (fault∗2 (Variable))
8 Terminal 4 input selection (Fixed) 0
90 0
10 Output stop (Fixed) 0
11 0 0
12 0 0
13 0 0
14 0 0
15 0 Fault occurrence
<Operation mode/drive unit setting>
* Writing is available depending on the Pr. 79 and
Pr. 340 setting. Refer to page 159 for details.
The restrictions depending on the operation
mode changes according to the computer
link specifications.
Mode Read Value
Written
Value
EXT H0000 H0010 *
PU H0001 H0011 *
EXT
JOG
H0002
NET H0004 H0014
PU+EXT H0005