Setting the parameter unit and operation panel
(2) Using the setting dial like a potentiometer to set the speed
Operation example Changing the speed from 0r/min to 1800r/min during operation
Operation Display
1.
Screen at power-ON
The monitor display appears.
2. Press to choose the PU operation mode.
PU indicator is lit.
3. Press to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously
appears.)
4. Turn until (Pr. 160) appears.
5. Press to read the present set value.
" "(initial value) appears.
6. Turn to change it to the set value " ".
7. Press to set.
Flicker Parameter setting complete!!
8. Change Pr. 161 to the setting value of " "
in the similar manner. (Refer to step 4 to 7.)
Flicker Parameter setting complete!!
9. Mode/monitor check
Press twice to choose the monitor/speed
monitor.
10.Press to start the drive unit.
11.Turn until " " appears.
The flickering speed is the set speed. You need
not press .
The speed flickers for about 5s.
REMARKS
If the display changes from flickering "1800" to "0", the setting of Pr. 161 Speed setting/key lock operation selection may not be "1".
Independently of whether the drive unit is running or at a stop, the speed can be set by merely turning the dial.
When the speed is changed, it will be stored in EEPROM as the set speed after 10s.
NOTE
When setting speed by turning setting dial, the speed goes up to the set value of Pr.1 Maximum setting (initial value:
3000r/min). Adjust Pr.1 Maximum setting setting according to the application.