Agilent Technologies 6813B Welding System User Manual


 
Language Dictionary - 3
111
TRIGger:SEQuence2:PHASe
TRIGger:SYNCHronize:PHASe
These commands set the phase angle with respect to an internal phase reference at which
PHASe:SYNChronous:SOURce becomes true. The range is from
360 to +360 degrees.
Command Syntax
TRIGger:SEQuence2:PHASe <NRf+>
TRIGger:SYNChronize:PHASe <NRf+>
Parameters
360 to +360 (degrees) | MAXimum | MINimum
*RST Value
0
Examples
TRIG:SYNC:PHAS 90 TRIG:SEQ2:PHAS 180
Query Syntax
TRIGger:SEQuence2:PHASe?
TRIGger:SYNChronize:PHASe?
Returned Parameters
<NR3>
Related Commands
ABOR TRIG TRIG:DEL TRIG:SYNC INIT
INIT:CONT *TRG WAI
TRIGger:SEQuence3
TRIGger:ACQuire
When the trigger subsystem has been initiated, these commands generate a measurement trigger
regardless of the selected trigger source. The measurement trigger causes the to digitize the
instantaneous output voltge and current for several output cycles and store the results in a buffer.
The FETCh commands return the requested calculation from this acquired data. When the measurement
completes, the WTG bit in the Status Operation Condition register is cleared.
Command Syntax
TRIGger:SEQuence3[:IMMediate]
TRIGger:ACQuire:[:IMMediate]
Parameters
None
Examples
TRIG:ACQ TRIG:SEQ3:IMM
Related Commands
ABOR TRIG TRIG:DEL TRIG:SYNC
TRIG:SYNC:PHAS INIT INIT:CONT *TRG WAI