Agilent Technologies 6813B Welding System User Manual


 
3 - Language Dictionary
50
MEASure:POWer:AC:APParent?
FETCh:POWer:AC:APParent?
Phase Selectable
These queries return the apparent power being sourced at the output terminals in volt-amperes.
Query Syntax
MEASure:[SCALar]:POWer:AC:APParent?
FETCh:[SCALar]:POWer:AC:APParent?
Parameters
None
Examples
MEAS:POW:AC:APP? FETC:POW:AC:APP?
Returned Parameters
<NR3>
Related Commands
MEAS:POW:REAC? MEAS:POW:PFAC?
MEASure:POWer:AC:REACtive?
FETCh:POWer:AC:REACtive?
Phase Selectable
These queries return the reactive power being sourced at the output terminals in volt-amperes reactive.
Reactive power is computed as:
VAR = sqrt(square(apparent power) square(real power))
Query Syntax
MEASure:[SCALar]:POWer:AC:REACtive?
FETCh:[SCALar]:POWer:AC:REACtive?
Parameters
None
Examples
MEAS:POW:AC:REAC? FETC:POW:AC:REAC?
Returned Parameters
<NR3>
Related Commands
MEAS:POW:AC:APP? MEAS:POW:PFAC?
MEASure:POWer:AC:PFACtor?
FETCh:POWer:AC:PFACtor?
Phase Selectable
These queries return the output power factor. The power factor is computed as:
pfactor = real power/apparent power
Query Syntax
MEASure:[SCALar]:POWer:AC:PFACtor?
FETCh:[SCALar]:POWer:AC:PFACtor?
Parameters
None
Examples
MEAS:POW:AC:PFAC? FETC:POW:AC:PFAC?
Returned Parameters
<NR3>
Related Commands
MEAS:POW:AC:APP? MEAS:POW:REAC?