Agilent Technologies 6813B Welding System User Manual


 
Language Dictionary - 3
83
PULSe:HOLD
This command specifies whether the pulse width or the duty cycle is to be held constant when the pulse
period changes. The following tables describe how the duty cycle, period, and width are affected when
one, two, or all three parameters are set in a single program message.
Command Syntax
[SOURce:]PULSe:HOLD <parameter>
Parameters
WIDTh | DCYCle
*RST Value
WIDTh
Examples
PULS:HOLD DCYC
Query Syntax
[SOURce:]PULSe:HOLD?
Returned Parameters
<CRD>
Related Commands
PULS:COUN PULS:DCYC PULS:PER PULS:WIDT
PULSe:HOLD = WIDTh
Parameter Set Action
DCYCle PERod WIDTh
Set Sets WIDTh. If WIDTh < PERiod, recalculates DCYCle; otherwise
recalculates the PERiod and DCYCle.
Set Sets PERiod. If WIDTh < PERiod, recalculates DCYCle; otherwise
recalculates the PERiod and DCYCle.
Set Set Sets WIDTh. If WIDTh < PERiod, sets the PERiod and
recalculates DCYCle; otherwise recalculates the PERiod and
DCYCle.
Set Sets DCYCle and recalculates the PERiod.
Set Set Sets DCYCle and WIDth and recalculates the PERiod.
Set Set Sets DCYCle and PERiod and recalculates the WIDTh.
Set Set Set Sets WIDTh. If WIDTh < PERiod, sets the PERiod and
recalculates DCYCle; otherwise recalculates the PERiod and
DCYCle.
PULSe:HOLD = DCYCle
Parameter Set Action
DCYCle PERod WIDTh
Set Sets WIDTh and recalculates the PERiod.
Set Sets PERiod and recalculates the WIDTh.
Set Set Sets WIDTh. If WIDTh < PERiod, sets the PERiod and
recalculates DCYCle; otherwise recalculates the PERiod and
DCYCle.
Set Sets DCYCle and recalculates the PERiod.
Set Set Sets DCYCle and WIDth and recalculates the PERiod.
Set Set Sets DCYCle and PERiod and recalculates the WIDTh.
Set Set Set Sets WIDTh. If WIDTh < PERiod, sets the PERiod and
recalculates DCYCle; otherwise recalculates the PERiod and
DCYCle.