Agilent Technologies 6813B Welding System User Manual


 
3 - Language Dictionary
72
LIST:COUNt
This command sets the number of times that the list is executed before it is completed. The command
accepts parameters in the range 1 through 9.9E37, but any number greater than 2E9 is interpreted as
infinity. Use INFinity to execute a list indefinitely.
Command Syntax
[SOURce:]LIST:COUNt <NRf+> | INFinity
Parameters
1 to 9.9E37 | MINimum | MAXimum | INFinity
*RST Value
1
Examples
LIST:COUN 3 LIST:COUN INF
Query Syntax
[SOURce:]LIST:COUNt?
Returned Parameters
<NR3>
Related Commands
LIST:CURR LIST:FREQ LIST:TTLT LIST:VOLT
LIST:CURRent
Agilent 6811B, 6812B, 6813B, Only
This command sets the sequence of peak output current list points. The current points are given in the
command parameters, which are separated by commas. The order in which the points are entered
determines the sequence in which they are output when a list is triggered. Changing list data while a
subsystem is in list mode generates an implied ABORt.
Command Syntax
[SOURce:]LIST:CURRent <NRf+> {,<NRf+>}
Parameters
refer to Specifications Table in User’s Guide
Unit
A
(peak current)
Examples
LIST:CURR 2.5,3.0,3.5
LIST:CURR MAX,3.5,2.5,MIN
Query Syntax
[SOURce:]LIST:CURRent?
Returned Parameters
<NR3> {,<NR3>}
Related Commands
LIST:CURR:POIN? LIST:COUN LIST:DWEL
LIST:STEP
LIST:CURRent:POINts?
Agilent 6811B, 6812B, 6813B, Only
This query returns the number of points specified in LIST:CURRent. Note that it returns only the total
number of points, not the point values.
Query Syntax
[SOURce:]LIST:CURRent:POINTs?
Returned Parameters
<NR1>
Examples
LIST:CURR:POIN?
Related Commands
LIST:CURR