Agilent Technologies 6813B Welding System User Manual


 
Language Dictionary - 3
49
Measurement Subsystem (Power)
This subsystem programs the power measurement capability of the ac source. Two measurement
commands are available: MEASure and FETCh. MEASure triggers the acquisition of new measurement
data before returning a reading. FETCh returns a reading computed from previously acquired data.
Individual outputs of a three-phase source are specified by the setting of INSTrument:NSELect.
Subsystem Syntax
MEASure | FETCh
[:SCALar]
:POWer
[:DC]? Returns the dc component of power
:AC
[:REAL]? Returns real power
:APParent? Returns VA
:REACtive? Returns VAR
:PFACtor? Returns power factor
:TOTal? Returns real 3-phase total power
MEASure:POWer?
FETCh:POWer?
Phase Selectable
These queries return the dc component of the power being sourced at the output terminals in watts.
Query Syntax
MEASure:[SCALar]:POWer[:DC]?
FETCh:[SCALar]:POWer[:DC]?
Parameters
None
Examples
MEAS:POW? FETC:POW?
Returned Parameters
<NR3>
Related Commands
MEAS:POW:AC?
MEASure:POWer:AC?
FETCh:POWer:AC?
Phase Selectable
These queries return the in-phase component of power being sourced at the output terminals in watts.
Query Syntax
MEASure:[SCALar]:POWer:AC[:REAL]?
FETCh:[SCALar]:POWer:AC[:REAL]?
Parameters
None
Examples
MEAS:POW:AC? FETC:POW:AC?
Returned Parameters
<NR3>
Related Commands
MEAS:POW?