Fluke PM-3370B Sander User Manual


 
COMMAND REFERENCE 4 - 61
INITiate[:IMMediate]
Syntax:
INITiate[:IMMediate]
Description:
This command causes the trigger system to be initiated once only, i.e., initiates
one acquisition cycle. The actual acquisition starts when all trigger conditions
have been met. After the acquisition has completed, the trigger system returns to
the IDLE state.
Note: The OPERation status bits 3 (SWEeping) and 5 (Waiting for TRIGger)
are valid when INITiate:CONTinuous is OFF and:
- the trigger mode is single-shot (TB MODE - single).
- the trigger mode is multiple-shot (TB MODE - multi).
Example:
Send
*
RST Resets the instrument.
Send
TRIGger:SOURce INTernal1 Trigger source becomes channel 1.
Send
TRIGger:LEVel .2 Trigger level becomes 0.2V.
Send
INITiate Single shot acquisition.
Send
TRACe? CH1 Queries channel 1 trace.
Read
<acquisition trace channel 1>
Note: For single-shot averaged acquisitions the trigger source must be one of
the input shannels (INTerval <n>), instead if IMMediate (software
automatic trigger).
Errors:
When an INITiate command is given while the trigger system is not in the IDLE
state, the message -213,"Init ignored" is generated.