Lincoln Electric IM10023 Welding System User Manual


 
A-4
INSTALLATION
MAXsa™ 10 CONTROLLER
A-4
FIGURE A.2 - HAND HELD PENDANT
Cover Screws
(4 places)
Pendant
Screws
( 2 Places)
K1543-xx
or K2683-xx
Arclink Cable
(Optional)
Cover
F
ront View
Cover removed
Access
Hole
1
3
2
INTERFACING TO THE MAXsa™ 10 CON-
TROLLER
The MAXsa™ 10 CONTROLLER is a versatile con-
troller. The User Interface can be removed and used
as a hand-held pendant. Most circuits can be accessed
through the screwless terminal strip. The auxiliary
relays can control standard Lincoln equipment, or they
can be used to control any other auxiliary equipment
custom controls. PLC interfacing to control starting,
stopping, motion, etc, can be accomplished with ease.
Using the Controller as a Hand-held Pendant:
1. Remove the 4 screws from the MAXsa™ 10 CON-
TROLLER that hold the cover. See Figure A.2.
2. Remove the 2 screws that hold the pendant in the
brackets. Use the acccess holes shown.
3. Extend the control cable as needed with an Arc Link
cable of appropriate length. See Figure A.2