Parameter Definition
Exit Setup Menu
P.0 This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
the setup menu
P.1 Wire Feed Speed Units
This option selects which units to use for displaying wire feed speed. English = inches/minute
wire feed speed units (default). Metric = meters/minute wire feed speed units.
P.2 Arc Display Mode
This option selects what value will be shown on the upper left display while welding. Amps =
The left display shows Amperage while welding (default). WFS = The left display shows Wire
Feed Speed while welding.
P.3 Display Energy
This option selects whether or not energy is shown on the lower display while welding. The total
energy from the previous weld will persist on the lower display until another weld is started, or a
user interface control is changed. This option will only show up in the list if the power source is
capable of calculating energy (a power source firmware update may be necessary).
No = Energy will not be displayed (default). Yes = Energy is displayed.
P.12 Travel Carriage Start/Stop - Travel Starts
This option allows the adjustment of the start and end travel options for a travel carriage. Press
the Right Button to enter the option and rotate the Control Knob to select either starting or end-
ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to
select the desired function. After selecting the function, press the Left Button to save the func-
tion and back out to select another option. Rotate the Control Knob to make another selection,
or press the Left Button to exit this option.
P.12 Travel Carriage Start/Stop - Travel Ends
This option allows the adjustment of the start and end travel options for a travel carriage. Press
the Right Button to enter the option and rotate the Control Knob to select either starting or end-
ing options. Press the Right Button to enter the selected option. Rotate the Control Knob to
select the desired function. After selecting the function, press the Left Button to save the func-
tion and back out to select another option. Rotate the Control Knob to make another selection,
or press the Left Button to exit this option.
P.13 Arc Force Adjustment Options
This option allows the adjustment of Arc Force values for Start, Weld and Crater. Press the
right Mode Select Button to enter the option and rotate the Set knob to select the desired weld
state to adjust. Press the right button again to adjust the value on the upper left knob. Press
the left button to save the value and back out to select another weld state. Rotate the Set knob
to make another selection, or press the left button to exit this option. P.13 will not appear if the
presently selected weld mode does not support Arc Force.
P.14 Reset Consumable Weight
Use this option to reset the initial weight of the consumable package. Press the Right Button to
reset the consumable weight. This option will only appear with systems using Production
Monitoring.