Lincoln Electric IM10023 Welding System User Manual


 
E-6
TROUBLESHOOTING
E-6
MAXsa™ 10 CONTROLLER
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Err 263 No usable weld modes. 1. The power source does not have
any welding programs loaded.
2. See the power source Instruction
Manual for load welding pro-
grams.
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.
ARCLINK SYSTEM ERROR CODES
Below are errors implemented for the MAXsa™ 10.
Typical User Interface 3 digit error codes (not blinked on the status LED).
Error
Code
N/A
28
83
84
Source
User Interface
Feeder
Feeder
Feeder
UI Text
" Limits Exceed "
"Gear Box Type"
“OUTPUT DISABLED”
" UI Shutdown 1 "
" UI Shutdown 2 "
Reason
When a mode is selected with a work point low limit
greater than the high WFS limit. (no event is logged)
The shutdown 2 input on the Feeder Board is open and
P.21 is selected for “Output Disable”
The shutdown 1 input on the Feeder Board is open.
The shutdown 2 input on the Feeder Board is open.
Error
Code
213
215
247
274
275
276
277
278
281
282
Source
User Interface
UI Text
Power Source
is Off-Line
Feeder Board is Off-Line
N/A
N/A
N/A
N/A
N/A
N/A
(Varies based on the
error type and who
caused the error)
(Varies based on the
error type and who
caused the error)
Reason
User Interface could not communicate with control board
in power source.
Either no feed head board is connected, being repro-
grammed or experiencing a fatal event.
Arc control has a latched fault. The UI will indicate a
Reset button needs to be pressed to clear the fault.
Weld set change required clearing of user memory.
UI memory could not be saved. Contact Lincoln Electric
Service Department for further support.
UI memory could not be restored. Contact Lincoln
Electric Service Department for further support.
UI memories were converted due to change in number of
UI parameters. Info only.
UI limits were converted due to change in number of UI
parameters with limits. Info only.
Internal Error. Collect all displayed values and contact
Lincoln Electric Service Department.
Internal Error. Collect all displayed values and contact
Lincoln Electric Service Department.