Lincoln Electric IM10023 Welding System User Manual


 
B-18
OPERATION
B-18
The Limits feature allows the operator to set minimum
and maximum values for various parameters depending
on the Weld Mode selected.
Each memory location may have a different set of limits,
even if the Weld Mode is the same. For example:
Memory Location 1 can be set for a maximum wire feed
speed of 140”/min; Memory Location 2 may be set for a
minimum of 100”/min and a maximum of 160”/min and
Memory Location 3 may have no WFS limit set.
Parameters are constrained by the machine limitations or
by memory limits. When the Memory Limits are enabled
the parameter will flash if an attempt is made to set a
value outside of the prescribed limit (if less than the
machine capabilities). The parameter will not flash if an
attempt is made to exceed the machine limits.
NOTE: Weld Modes cannot be selected through the
Limits Setup Menu. They must be chosen and
saved before entering the Limits Menu.
SETTING LIMITS
1. Press and hold the desired Memory Button until
the LED for that location begins to blink rapidly.
• The MSP Display will read:
2. After 2 seconds the display will change to show the
following items:
• Memory Value
• High Limit
• Low Limit
• Parameter Name
3. The Parameter Name on the MSP Display will
flash to indicate it is ready to be changed. If no lim-
its were previously set, the High and Low values
are the limits of the Power Source
• Press the Arc Start/End Options button to select
that parameter.
• Use the Mode Select Panel Control to adjust the
High Limit (flashing).
• Press the Arc Start/End Options button.
• Use the Mode Select Panel Control to adjust the
Value (flashing).
• Press the Arc Start/End Options button.
• Use the Mode Select Panel Control to adjust the
Low Limit (flashing).
• Press the Arc Start/End Options button.
• Use the Mode Select Panel Control to select
another Parameter Name (flashing) and repeat
the above sequence until all Limits are set.
4. Press the selected Memory when all limits are set
to desired values. The MSP Display will read:
• Use the Weld Mode Select or the Arc Start/End
Options button to either save (yes) or discard
(no) the changes.
MAXsa™ 10 CONTROLLER
OPTIONAL LIMIT SETUP
Memory 1
Set Limits
200
Hi=1050 Lo= 200
Weld Amps
Set High
Limit
V
alue
L
ow Limit
Set Low
Limit
Parameter
N
ame
Save Limits
Yes No