Lincoln Electric SVM101-B Welder User Manual


 
V300-I
TROUBLESHOOTING & REPAIR
F-28 F-28
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
SWITCH BOARD TEST (CONT.)
Apply Positive Apply Negative
Test Prove to Test Probe to
Terminal Terminal Test Result Conclusion Repair Action Next Procedure Notes
12 401/403 Greater than OK None Continue
1K ohm
Less than Shorted Replace both Snubber Test
100 ohms Switch Boards
401/403 12 Less than OK None Continue
100 ohms
Greater than Open Replace both Snubber Test
1K ohm Switch Boards
9 402/404 Less than OK None Continue
100 ohms
Greater than Open Replace both Snubber Test
1K ohm Switch Boards
402/404 9 Greater than OK None Continue
1K ohm
Less than Shorted Replace both Snubber Test
100 ohms Switch Boards
TABLE F.3
SWITCH BOARD RESISTANCE CHECKS