Lincoln Electric SVM161-A Welding System User Manual


 
CN2
41
1
2
3
4
42
45
CN1
44
1
2
3
4
7
8
65
48
52
53
54
CN7
2
3
5
6
73
76
1
4
72
71
58
FIGURE F.10 – PLUGS CN1, CN2 & CN7
CONTROL/DISPLAY BOARD TEST (continued)
TROUBLESHOOTING AND REPAIR
F-26 F-26
INVERTEC® V205-T AC/DC™
Table F.2 Plug CN1 Test Points
Table F.3 Plug CN2 Test Points
Table F.4 Plug CN7 Test Points
Wire #
52
53
54
44
48
58
Description
Solenoid Valve Ground
Trigger
Trigger
Start High Frequency
High Frequency Ground
Start Solenoid Valve
Expected Voltage
-------
-------
-------
-------
-------
48 VDC
Wire #
71
72
73
74
75
76
Description
Ext
Ext
Ext Ground
Ext Trigger
Ext Ground
Ext Ground
Expected Voltage
5 VDC
-------
-------
-------
-------
-------
Wire #
41
42
45
Description
Supply
Supply
Ground for Supplies
Expected Voltage
24 VDC
48 VDC
-------
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC