Lincoln Electric SVM161-A Welding System User Manual


 
BUS BOARD
FIGURE F.11 – BUS BOARD LOCATION
BUS BOARD TEST (continued)
PROCEDURE
1. Remove input power to the V205-T machine.
2. Using a phillips head screwdriver, remove the
case wraparound cover.
3. Perform the Capacitor Discharge Procedure
detailed earlier in this section.
4. Locate the Bus board and associated plugs.
Do not remove plugs from the board. See
Figure F.11.
5. Carefully apply the correct input voltage to the
V205-T and check for the correct voltages per
Tables F.5, F.6, F.7, F.8 & F.9
6. Machine should be set to “STICK” mode.
TROUBLESHOOTING AND REPAIR
F-28 F-28
INVERTEC® V205-T AC/DC™
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC