This is the typical AC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 2 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+) probe to
electrode, (–) probe to work.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
AC STICK MODE
TROUBLESHOOTING AND REPAIR
F-31 F-31
PRECISION TIG® 225
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
Perform all voltage and waveform checks with high frequency circuit OFF.
Perform High Frequency Disable Procedure.
____________________________________________________________________
0volts
2ms
50
volts