RETEST AFTER REPAIR
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could
affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine
must be retested.
Input Volts/Hertz Maximum Idle Amps
208/60 2.70 Amps
230/60 3.00 Amps
Stick Mode OCV
AC 70 - 75VAC
DC 55 - 66VDC
TIG Mode OCV
AC 70 - 80VAC
DC 60 - 66VDC
DC TIG Mode 5 Amps @ 12 Volts
DC TIG Mode 225 Amps @ 29 Volts
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE -
AT MINIMUM OUTPUT SETTINGS
MINIMUM ACCEPTABLE OUTPUT VOLTAGE -
AT MAXIMUM OUTPUT SETTINGS
RECOMMENDED METERS FOR MACHINE OUTPUT TESTS
VOLTMETER: AC and DC True RMS Meter - Fluke 8922A or equivalent
AMMETER: Columbia Type AX AC or DC Tong Ammeter
IMPORTANT: IF OTHER TYPE METERS ARE USED RESULTS MAY NOT BE ACCURATE.
INPUT IDLE AMPS
OPEN CIRCUIT VOLTAGES