MACHINE LOADED TO 180 AMPS AT 16VDC.
This is the typical DC (+) output voltage wave-
form generated from a properly operating
machine. Note that each vertical division repre-
sents 10 volts and that each horizontal division
represents 2 milliseconds in time. The machine
was loaded with a resistance grid bank. The grid
load meters read 180 amps and 16VDC
Note: Scope probes connected at machine out-
put terminals: (+) probe to electrode, (–) probe to
work.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
DC TIG MODE
TROUBLESHOOTING AND REPAIR
F-34 F-34
PRECISION TIG® 225
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
Perform all voltage and waveform checks with high frequency circuit OFF.
Perform High Frequency Disable Procedure.
____________________________________________________________________
0volts
2ms
50
volts