OM-4409 Page 13
SECTION 4 − SPECIFICATIONS
4-1. Weld, Power, And Engine Specifications
Welding
Mode
Weld
Output
Range
Rated
Welding
Output
Maximum
Open-Circuit
Voltage
(Nominal)
Generator Power
Rating
Engine
Engine
Oil
Capacity
Fuel Tank
Capacity
CC/DC 20 − 750 A
500 A,
40 Volts
DC,
95
Standard
CV/DC 14 − 40 V
DC,
100% Duty
Cycle
600 A,
56
Standard
Single-Phase,
4 kVA/kW, 34/17 A,
120/240 V AC
,
DEUTZ
CC/AC
(Optional)
20 - 575
600 A
,
44 Volts
DC,
40% Duty
Cycle
64
120/240 V AC
,
50/60 Hz
3-Phase Generator
Option*
Single-Phase/Three-Phase,
Deutz BF4M2011
Oil-Cooled,
Four-Cylinder,
Turbo-Charged
63 4 HP Diesel Engine
11 qt
(10.4 L)
25 gal
(95 L)
Battery
Charge/
Jump
Start
12/24 V
750 A,
12 Volt
Jump Start
750 A,
24 Volt
Jump Start
14/28
Single Phase/Three Phase,
12/20 kVA/kW, 50/48A,
120/240 VAC, 60 Hz
*In Addition To Standard
4 kVA/kW Generator Power
63.4 HP Diesel Engine
4-2. Air Compressor Specifications
Compressor Model
And Type
Air Output At Effective
Working Pressure
Factory Pressure
Setting
Safety Relief
Valve Rating
Air Compressor
Oil Capacity
Ingersoll Rand CE55 G
Rotary Screw
60 scfm (1.7 m
3
min
−1
),
100 psi (690 kPa),
100% Duty Cycle
125 psi (862 kPa) 150 psi (1034 kPa) 4 qt (3.8 L)
4-3. Sound Level Table
Idle Speed (1235 rpm)
Weld/Power Speed
(1850 rpm)
40 Volts DC At 500
Amps
44 Volts DC At 600
Amps
Air Compressor On
96.6 Lwa sound power
71.7 dBa at 23 ft (7 m)
77.2 dBA 3.3 ft (1 m)
from front panel
102.8 Lwa sound power
77.9 dBa at 23 ft (7 m)
83.0 dBA 3.3 ft (1 m)
from front panel
103.9 Lwa sound power
79.0 dBa at 23 ft ( 7 m)
89.8 dBA 3.3 ft (1 m)
from front panel
106.0 Lwa sound power
81.1 dBa at 23 ft (7 m)
93.3 dBA 3.3 ft (1 m)
from front panel
Air Compressor Off
94.6 Lwa sound power
69.7 dBa at 23 ft (7 m)
74.5 dBA 3.3 ft (1 m)
from front panel
100.6 Lwa sound power
75.7dBa at 23 ft (7 m)
78.8 dBA 3.3 ft (1 m)
from front panel
103.0 Lwa sound power
78.1dBa at 23 ft (7 m)
86.0 dBA 3.3 ft (1 m)
from front panel
104.5 Lwa sound power
79.6 dBa at 23 ft (7 m)
91.8 dBA 3.3 ft (1 m)
from front panel