OM-4409 Page 52
10-2. Routine Air Compressor Maintenance
. See Section 9 for engine/generator maintenance information.
! Stop engine before maintaining.
. See Compressor Maintenance Label for im-
portant start-up, service, and storage infor-
mation. Service air compressor more often
if used in severe conditions.
Recycle air
compressor
fluids.
n = Check Z = Change ~ = Clean l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
Section 5-7
~ Spills n Oil Level
Every
100
Hours
n Air Cleaner Hoses
Every
250
Hours
Section
10-3
l Unreadable Labels n Belt Tension ~ Cooling System nAir Filter Element
l Worn or Damaged Air/Oil
Hoses
Every
500
Hours
Section
10-5
Z Oil Z Oil Filter
Every
1000
Hours
Section
10-5
Z Air/Oil Separator