4-5. Stick And MIG Volt-Ampere Curves
208 135 / 203 415 / 208 956
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
C. MIG Mode
A. DC Stick Mode
B. AC Stick Mode (Optional)
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900 1000
DC AMPERES
DC VOLTS
Ranges
300 Max
185 525
125 400
85 250
55 125
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900 1000
DC AMPERES
DC VOLTS
MAX
MIN
0
20
40
60
80
100
0 100 200 300 400 500 600 700
AC AMPERES