Miller Electric OM-4409 Welding System User Manual


 
OM-4409 Page 40
8-3. Battery Charge Cable Connections
! Stop engine.
! Do not charge or jump start a battery
which has loose terminals or one
showing damage such as a cracked
case or cover.
! Have only qualified persons do bat-
tery charging work.
! Keep cables away from moving
parts.
! Do not use damaged cables.
! Be sure charger output voltage
matches battery voltage.
! Read BCI Battery Service Manual
before charging or jump starting.
. Before connecting to battery, place
Output Selector switch in position
matching voltage of battery being
charged.
1 Battery
2 Battery Charging Cables
For battery charging, use less than 20 feet
(6.1 m) of AWG #1 or larger cable. For jump
starting, use less than 20 feet (6.1 m) of
AWG 2/0 or larger cable.
3 Terminal Lug
Use lugs of proper amperage capacity and
hole size for connecting to charge output
terminals.
Install suitable connectors on remaining
ends of battery cables.
4 Battery Charge Positive (+) Output
Terminal
5 Battery Charge Negative () Output
Terminal
. Connect charging cables to battery
charge output terminals before con-
necting to battery terminals.
Connect Battery Charge Positive (+) cable
to battery positive (+) terminal, and battery
Charge Negative () cable to battery nega-
tive () terminal.
803 231-A / 210 156 / Ref. S-0714 / Ref. S-0756
1
3
2
+
4
5