Mitsubishi Electronics E70 Router User Manual


 
E70 Series Connection Manual
4.2 Connection of Control Unit
79
4.2.3 Connecting with Emergency Stop Signal
Connect the emergency stop switch to EMG connector by F120 cable.
<Related items>
Cable drawing: "Cable: F120 Cable"
Besides the emergency stop input from the NC controller, double-protection when an emergency stop occurs can be
provided by directly inputting an external emergency stop to the drive unit. Even if the emergency stop is not input from
NC for some reason, the contactors can be shut off by the external emergency stop input.
Outlines are shown below. For more details, refer to the Instruction Manual of each drive unit.
<Drive unit (MDS-DM2-SPV) external emergency stop: Example 1>
EMG
F120
+24V
3
2
1
3
2
1
EMGIN
LG
R
FG
EMG
Emergency stop input circuit
NC control unit
NC control unit
Emergency
stop switch
Emergency
stop switch
+24V
EMGIN
LG
FG
EMG
CN9B
EMG
F120
+24V
0V(LG)
3
20
3
2
1
3
2
1
MDS-DM2-SPV
R
MDS-DM2-SPV
R
NC control unit
Stabilized
power supply
Emergency
stop switch
Emergency stop input circuit
NC control unit