Mitsubishi Electronics E70 Router User Manual


 
E70 Series Connection Manual
2.2 Control Unit
15
(11) Remote I/O unit I/F (RIO1)
Up to eight remote I/O stations can be connected.
<Cable side connector type>
Connector: 1-178288-3
Contact: 1-175218-2 x3
Recommended manufacturer: Tyco Electronics
(12) Menu key I/F (MENUKEY)
(13) Encoder input 1ch/ 5V manual pulse generator input 2ch (ENC)
Synchronous feed encoder or 5V manual pulse generator can be connected to this connector.
* Connect connector case with FG pattern.
<Cable side connector type>
Plug: 10120-3000VE
Shell: 10320-52F0-008
Recommended manufacturer: 3M
1 I/O TXRX1
2 I/O TXRX1*
3 0V
1 0V 11 0V
2 I ENC1Z 12 IENC1Z*
3 I ENC1B 13 IENC1B*
4 I ENC1A 14 IENC1A*
5 0V 15 0V
6 O5V 16 O5V
7 IHA2A 17 IHA2B
8 IHA1A 18 IHA1B
9 NC 19 NC
10 O5V 20 O5V
13
10 1
20 11