Mitsubishi Electronics E70 Router User Manual


 
2 General Specifications
MITSUBISHI CNC
10
2.1 Environment Conditions
(Note 1) "Short term" means within one month.
(Note 2) For the current value of the I/O circuit, calculate with the number of points used and load.
(Note 3) For the heating value of the I/O circuit, calculate with the number of points used.
(Note 4) Allows only the amount to be consumed by control circuit.
(Note 5) Differs according to the number of machine input operation points and the load and number of points
connected to the machine output. The maximum value applies when all points are ON.
(Note 6) These units, which are open equipments, must be installed within a sealed metal control panel.
(Note 7) FCU7-KB926 does not need 24VDC power supply input.
Item
Unit name Control unit Display unit Keyboard unit
Operation panel
I/O unit
Machine operation
panel
Type FCU7-MU558 FCU7-DU120-13 FCU7-KB024/025
FCU7-DX621/711/
721/731
FCU7-KB921/926
Gener
al
specifi
cation
s
Ambient
temperature
During
operation
0 to 55C°
During
storage
-20 to 60C°
Ambient
humidity
Long
term
10 to 75% RH (with no dew condensation)
Short
term
10 to 95% RH (with no dew condensation) (Note 1)
Vibration
resistance
4.9m/s
2
or less (during operation)
Shock
resistance
29.4m/s
2
or less (during operation)
Working
atmosphere
No corrosive gases, dust or oil mist
Requir
ed
power
specifi
cation
s
Power voltage
24VDC ±5%
Ripple noise 200mV
(P-P)
3.3V/12VDC 5VDC 3.3V/5VDC
24VDC ±5%(Note 7)
(Provided by the control unit)
Power capacity
24V 2.5A - -
-
(Note 2)
0.25A(Note 7)
Instantaneous stop
tolerance time
20ms - 20ms(min)(Note 7)
Others
Heating
value
(max.)
12.0W 3.3W 1.0W
Control section: 5.0W
(Note 3)
6W
Mass (kg)
1.0 1.5 0.8 0.4
FCU7-KB921:1.2
FCU7-KB926:0.5
Outline
dimension
(mm)
235(width) x
173(height) x
73(depth)
(Depth from the plate
mounting surface: 60)
260(width) x
200(height)
140(width) x 200(height)
120(width) x
180(height)
FCU7-KB921:
260(W) x 140(H)
FCU7-KB926:
140(W) x 140(H)
Item
Unit name Remote I/O unit
Type FCUA-DX101 FCUA-DX111 FCUA-DX121 FCUA-DX141
General
specifications
Ambient temperature
During
operation
0 to 55C°
During
storage
-20 to 60C°
Ambient humidity
Long term
10 to 75% RH (with no dew condensation)
Short term 10 to 95% RH (with no dew condensation) (Note 1)
Vibration resistance
4.9m/s
2
or less (during operation)
Shock resistance
29.4m/s
2
or less (during operation)
Working atmosphere
No corrosive gases or dust
Required power
specifications
Input power voltage
24VDC±5% Ripple noise 200mV (P-P)
Power capacity
24V 0.7A (Note 4) 24V 1.5A (Note 4) 24V 0.7A (Note 4)
Instantaneous stop
tolerance time
-
Others
Heating value (max.)
25W (Note 5) 30W (Note 5) 30W (Note 5)
Mass (kg)
0.5 0.6 0.6 0.6