Mitsubishi Electronics E70 Router User Manual


 
2 General Specifications
MITSUBISHI CNC
20
(18) LED
Name Function At fault Conditions
24VDCIN 24VDC input check Not lit
(1) Failure of 24VDC input
(2) Fuse is disconnected near DCIN connector
DCOUT Internal output voltage check Not lit
(1) Failure of internal voltage output in control unit
(2) Short circuit of 5VDC output on CG71 or ENC
LCDON
12VDC output voltage check
for backlight driver
Not lit
(1) Failure of 12VDC output in control unit
(2) 24VDC input voltage is +20V or less
PSEMG
External emergency stop
status display
Lit (Red) External emergency stop signal has inputted
WDER System error display Lit (Red)
(1) Failure of control unit
(2) SRAM data is broken
BATALM Battery voltage drop Lit (Red) Battery voltage has dropped to 2.7V or less
Name