Mitsubishi Electronics E70 Router User Manual


 
2 General Specifications
MITSUBISHI CNC
40
[Outline of analog signal output circuit]
The analog signal output circuit can be used only for FCUA-DX121.
Output circuit
Output conditions
(Note) n=(2
0
to 2
11
)
Output voltage 0V to ±10V (±5%)
Resolution 12bit (±10V × n/4096) (Note)
Load conditions 10k load resistance
Output impedance 220
CAUTION
1. When using an inductive load such as a relay, always connect a diode in parallel to the load.
2. When using a capacitive load such as a lamp, always connect a protective resistor serially to the load to
suppress rush currents.
DAC
R
220
R
AO
AO*
0V(RG)