Mitsubishi Electronics M70V Router User Manual


 
4 Connection
MITSUBISHI CNC
112
<Software Interface>
Machine operation panel occupies RIO station No. 4 to 6. The device numbers for switch and LED on operation
panel are fixed as listed below.
The following lists the devices for using the RIO 1st channel.
Table: Device No. for Machine operation panel
(1) Machine operation panel B (Switch)
Machine operation panel B is equipped with rotary switches (cutting override, spindle override) and a selector
switch (memory protection key), and an emergency stop button. Direct wiring connection will be applied to the
emergency stop button, and device numbers for other switches are defined as listed below.
(a) Cutting override (6bit)
21 position code list
Station
Device No.
Detail
RIO1 RIO3
1
X00 X1F/Y00 Y1F X200 X21F/Y200 Y21F
2
X20 X3F/Y20 Y3F X220 X23F/Y220 Y23F
3
X40 X5F/Y40 Y5F X240 X25F/Y240 Y25F
4
X60 X7F/Y60 Y7F X260 X27F/Y260 Y27F
Machine operation panel B
(Switch)...16 points vacant
5
X80 X9F/Y80 Y9F X280 X29F/Y280 Y29F
Machine operation panel A
(Key switch/LED)
6
XA0 XBF/YA0YBF
X2A0X2BF/Y2A0
Y2BF
Machine operation panel A
(Key switch/LED)
7
XC0 XDF/YC0 YDF
-
8
XE0 XFF/YE0 YFF
-
Device No.
Setting value X60 X61 X62 X63 X64 X65
0 000000
1 100001
2 110000
3 010001
4 011000
5 111001
6 101000
7 001001
8 001100
9 101101
10 111100
11 011101
12 010100
13 110101
14 100100
15 000101
16 000110
17 100111
18 110110
19 010111
20 011110