E70 Series Connection Manual
2.6 Remote I/O Unit
39
(3) Machine output (DO-L)
(4) Machine output (DO-R)
Use within the specification ranges shown below.
Output circuit
Output conditions
(Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance 100V or more,
100mA or more) in parallel to the load.
(Note 2) When using a capacitive load such as a lamp, always connect a protective resistor (R=150Ω) serially to
the load to suppress rush currents. (Make sure that the current is less than the above tolerable current
including the momentary current.)
Insulation method Non-insulation
Rated load voltage 24VDC
Max. output current 60mA/point
Output delay time 40μs
R
RA
DO-L/DO-R
PL
Source type (DX1x1)
24VDC(+)
Control
circuit
(Machine side)