Mitsubishi Electronics M70V Router User Manual


 
E70 Series Connection Manual
2.2 Control Unit
13
(5) External emergency stop input (EMG)
* Be sure to connect EMG terminal cable (G123) to the connector when not used.
<Cable side connector type>
Connector: 005057-9403
Contact: 0016020103
Recommended manufacturer: MOLEX
(6) Expansion card slot (ADONCCB)
(7) Display unit signal I/F (LCD)
(8) Optical communication I/F (OPT)
<Cable side connector type>
(PCF type)
Connector: CF-2D101-S
Recommended manufacturer: Japan Aviation Electronics
(POF type)
Connector: PF-2D101
Recommended manufacturer: Japan Aviation Electronics
1 FG
2 I EMG IN
3 O +24V
31