MQ SP-3035 CONCRETE SAW — OPERATION AND PARTS MANUAL — REV. #3 (09/29/06) — PAGE 47
MQ SP-3035 CONCRETE SAW
6. Loosen the Mounting Bolt and remove the Outer Flange and Bushing.
7. Inspect the Inner Flange to ensure the proper seating of the tapered fit.
The Inner Flange should be seated between .030” and 0.0” (flush) to the end of the Spindle.
Fig. 33 — Proper seating of the Inner Flange and Spindle
8. Test to ensure that the Inner Flange does not wobble when rotated. Use a dial indicator on the
face of the Flange. Maximum tolerance is .003” run-out on the face of the Flange.
NOTE
For Spindle Maintenance/hydraulic oil change see page 58.