Circuit Breakers
Three thermal circuit breakers are located behind the Control Panel access cover.
Fig. 37 — Circuit Breaker location
Under normal circumstance circuit breakers do not require service; they are automatically re-set
once an overload condition has been corrected. If one or more breakers are cycling on/off, locate
the cause of the electrical overload and repair as required.
Also see the Electrical Schematic on page 61.
Maximum Cut Depth Adjustment
The 3000 Series saws come factory-adjusted for maximum usable cut depth. However, should
you desire to adjust the maximum depth:
1. Park the blade-less saw on a flat and level surface.
2. Fully lower the saw onto the Stop Bolts (see Fig. 38).
3. Measure the distance from the Blade Flanges to the surface.
4. Adjust the Stop Bolts in or out until the Blade Flanges have 1/8” to 3/16” ground clearance.
5. Ensure that both bolts are adjusted to the same setting so that the load is evenly distributed.
Remove Dash Panel to
access circuit breakers