Sterling 882.01749.00 Welder User Manual


 
882.01749.00 32 of 93
2. The following applications require a larger feed stand (optional 3” or 4”) to prevent
material bridging:
o Machines with a total throughput over 200 lbs./hr.
o Machines running regrind larger than 5/16” screen size
o Processes with a high percentage of regrind (>30%)
o Non-free flowing virgin material, i.e. powder
o Consult factory for any special requirements.
3. Optimum mounting of the Digital Dosing feeder is shown in Figure 4, with the additive
being dosed in the first few flights of the feed screw.
4. The controller should be remote mounted for operator convenience. The control unit
must not be exposed to temperatures above 45° C (115° F), or excessive moisture.
5. Electrical connection to process machine:
Injection Molding: Connect the “cycle/run” cable (thin, gray two-conductor
cable) to a set of dry (NO VOLTAGE) contacts that CLOSE
for the duration of the screw recovery. (See Figure 5.)
TB #10
X5
Relay contact
Injection molding Digital Dosing controller
Figure 5. Electrical Interface Connection Diagram –
Injection Molding or Extrusion - Constant