Sterling 882.01749.00 Welder User Manual


 
882.01749.00 68 of 93
Chapter 4: Maintenance
4-1 Preventative Maintenance Intervals
Daily:
Check warning signs on equipment for good legibility and
completeness.
Weekly:
Check function of the “On/Off” Switch.
Check shear plate and mounting hardware in “DD” dosing
station.
Every 3
months:
Check wiper and mounting hardware in “DT” dosing station.
Every 6
months:
Check that all electrical and mechanical connections are
tight.
Check adjustment of the level probes (optional).
Annually:
Check dosing disc in dosing station DD and DT.
Each time
after material
Is changed:
Clean the dosing station.
Check shear plate or wiper.
Check dosing disc.
CAUTION: Always disconnect power and remove the dosing
module from the motor assembly before taking the
dosing module apart.
Injury could result if fingers are pinched between
the rotating disc.