Turbomachinery Package Specification Taurus 60 Compressor Set and Mechanical Drive
13.1.2 Self-Cleaning Barrier Type Air Filter
The self-cleaning barrier type air filter system is suitable for extreme environments where
dust loading or cold-weather operation is a concern. This system is available in an
updraft configuration. This system requires a suitable supply of cleaning air. Cleaning air
can be provided by the customer or supplied using turbine compressor discharge
pressure (Pcd) bleed air. If bleed air is used, an air heat exchanger is provided for
mounting in the air inlet ducting between the air inlet filter and the turbine air inlet.
Standard features include:
Support leg kit (Filter house only)
Dual differential pressure alarm and shutdown switch
Filter elements
Air treatment module
Differential pressure gauge
Electrical connections prewired to a common junction box
Access to change filter elements from below must be provided
13.1.3 Marine / Offshore-High Velocity Type Air Filter
The marine and offshore high velocity air filter system (Figure 25) is suitable for use in
many offshore applications. This system provides removal of salt, water, and particulates.
This system consists of:
First stage marine vane separator/moisture eliminator
Second stage prefilter
Third stage bag filters
Fourth stage marine vane separator/moisture eliminator
Access doors are provided in the first stage marine vane separator/moisture eliminator
for filter removal. Standard features include:
Drainage system
Transition outlet flange
Lifting lugs
Instrumentation panel
Differential pressure gauge
Quad Certified Differential Pressure Transmitter
2 Different Final Filter element types available (HVL, HVX)
HVX filter elements allow for a higher level of filtration. This is recommended for
environments with moderate dust loading expectations. The pressure drop on HVX filter
elements will be higher than HVL elements.