FibreSTORE RAID System: Rack Installation Guide
Supported Rack Configurations
Ciprico supports four certified configurations of FibreSTORE RAID components in a
Ciprico rack. The product numbers for these rack configurations are:
AAMK36A
AAMK36A2
AAMK36A3
AAMK36A4
In the following pages, each rack configuration is described for a fully-loaded rack. If your
rack is not going to be fully loaded, leave the bottom slots empty and cover them with filler
panels.
Configuration for One RAID System (AAMK36A)
Figure 3 shows a front view of a fully-loaded rack with:
Filler panels. These should be located as shown in the figure to
guarantee air flow for cooling.
FibreSTORE RAID controller enclosure. This should be
located in the top position.
Disk enclosures. These should be installed directly below the
FibreSTORE RAID controller enclosure. Any empty slots
should be located near the bottom of the rack.
The Cache Retention Unit (CRU) is always located at the
bottom of the rack.
Figure 3. AAMK36A Rack Configuration
2545.vsd
Disk Enclosure 0
Disk Enclosure 1
Disk Enclosure 2
Disk Enclosure 3
Disk Enclosure 4
Disk Enclosure 5
Disk Enclosure 6
FibreSTORE RAID
Filler Panel
Panel covering CRU
Filler Panel