Emerson 2330MKII Welding System User Manual


 
BOOK 0958-B
31
SECTION VI
RATINGS AND SPECIFICATIONS
RATINGS
1. Duty ..................................................................................................................................................... Continuous
2. Horsepower Range ............................................................................................ 1/6 - 3 HP (See Table 1, Page 2)
3. Line Fuse Interrupting Capacity ...............................................................................................100,000 Amperes
4. Line Power ........................................................................................115V or 230V, Single-Phase, 50 Or 60 Hz
5. Motor Speed Potentiometer ........................................................................................................ 5K Ohms, 1/2W
6. Overload Capacity, Armature Circuit....................................................................................150% For 1 Minute
7. Timed Overload Threshold .......................................................................................................................... 120%
8. Service Factor....................................................................................................................................................1.0
TABLE 8. TYPICAL APPLICATION DATA
COMPONENT RATINGS
RATED HORSEPOWER (HP) 1/6 1/4 1/3 1/2 3/4 1 1-1/2 2 3
RATED KILOWATTS (kW) 0.124 0.187 0.249 0.373 0.560 0.746 1.120 1.492 2.238
115V
Unit
3.9 5.0 6.0 8.7 12.4 15.8 NA NA NA
Line
Amps
230V
Unit
NA NA NA 4.2 5.9 8.8 12.6 15.8 22.0
1-PHASE
AC INPUT
(FULL-LOAD)
KVA 0.48 0.58 0.71 1.00 1.40 2.00 3.00 4.00 5.00
90V 2.0 2.8 3.5 5.4 8.1 10.5 NA NA NA
Motor
Armature
Amps
180V NA NA NA 2.6 3.8 5.5 8.2 11.6 15.1
Model
2331
2335
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 NA
DC OUTPUT
(FULL-LOAD)
Motor
Field
Amps
(Maximum)
Model
2332
2336
1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
FULL-LOAD TORQUE (lb-ft) with
1750 RPM Base Speed Motors
0.5 0.75 1.0 1.5 2.2 3.0 4.5 6.0 9.0
MINIMUM TRANSFORMER KVA FOR
VOLTAGE MATCHING OR ISOLATION
0.5 0.75 0.75 1.0 1.5 2.0 3.0 5.0 7.5