Instruction syntax: Instruction description:
$ID;001;k;LPB<CR> RI stand-by status (all valves closed)
$ID;002;k;LPB<CR> RI sample gas valve open
$ID;003;k;LPB<CR> RI zero gas valve open
$ID;005;m;k;LPB<CR> RI span gas valve open
$ID;006;LPB<CR> RI on - line status
$ID;007;LPB<CR> RI off - line status
$ID;008;LPB<CR>
*)
SP pump status
*)
$ID;009;w;LPB<CR>
*)
RI pump status
*)
$ID;011;m;k;LPB<CR> SP at full scale range
$ID;013;k;LPB<CR> SP t
90
(response time)
$ID;014;w;k;LPB<CR> RP t
90
(response time)
$ID;017;k;LPB<CR> SP preflushing period (zero gas)
$ID;018;w;k;LPB<CR> RP preflushing period (zero gas)
$ID;019;k;LPB<CR> SP preflushing period (span gas)
$ID;020;w;k;LPB<CR> RP preflushing period (span gas)
$ID;023;k;LPB<CR> SP concentration
$ID;028;m;k;LPB<CR> SP span gas concentration
$ID;029;m;w;k;LPB<CR> RP span gas concentration
$ID;030;LPB<CR> SP status messages
$ID;031;t;LPB<CR> SP serial number (t=0, max. 10 characters)
channel identification (t=1: ch.1, t=2: ch. 2)
$ID;603;k;LPB<CR> SP gas component
$ID;604;k;LPB<CR> RI automatic zeroing
$ID;605;k;LPB<CR> RI automatic spanning
$ID;606;0;LPB<CR> RI automatic zeroing & spanning
$ID;626;LPB<CR> SP E-Prom / Software version
$ID;627;LPB<CR> SP failure message (possible error batt. is
clearing by read out)
$ID;645;0;LPB<CR> SP pressure value
$ID;646;w;LPB<CR> SP solenoid valve status (w=1: samplegas valve,
w=2: zerogas valve, w=4: spangas 1, w=8: spangas 2)
INSTRUCTION LIST
w=0: pump Off, w=1: pump On
*)
BINOS
®
100 2M/F from program version 5.0 is required