Graco 313289s Paint Sprayer User Manual


 
Alarms
313289S 27
V1M Voltage low control Always Voltage dropping below 9 Vdc
from power supply.
Change air filter in control filter
regulator. See Replace Air Fil-
ter Element, page 31.
Check the pressure setting is
18 psi (0.12 MPa, 1.24 bar) on
turbine air regulator.
Check voltage on information
screen.
Turbine not spinning with air on. Replace air turbine cartridge.
See Alternator Power Supply
Control Components, page
38.
N6C Display has no signal. Always No display communication sig-
nal.
Check cable connections.
Replace display.
Machine powered down in
spray mode.
Press stop button before turning
off power.
DLA A air motor reed switch signal
missing advisory.
Always Reed switch does not see the
air motor magnet.
Replace air motor reed switch
magnet.
Reed switches are bad. Replace air motor reed switch.
Prevent air motor icing. See
advisory P9A and P9B.
Air motor is icing up.
DLB B air motor reed switch signal
missing advisory.
Always Reed switch does not see the
air motor magnet.
Replace air motor reed switch
magnet.
Reed switches are bad. Replace air motor reed switch.
Prevent air motor icing. See
advisory P9A and P9B.
Air motor is icing up.
DMA A air motor linear sensor
jump advisory.
Always System ran out of fluid. Add fluid to the system.
Linear sensor is bad. Replace linear sensor.
DMB B air motor linear sensor
jump advisory.
Always System ran out of fluid. Add fluid to the system.
Linear sensor is bad. Replace linear sensor.
Optional User-Settable Maintenance Warnings
MAA
MAB
Maintain pump Always, if enabled Pump usage exceeds user-set
limit. Maintenance due.
Service pump. See Pump
Assembly, page 44.
MEA
MEB
Maintain dosing valve Always, if enabled Dosing valve usage exceeds
user-set limit. Maintenance
due.
Service dosing valve. See Dos-
ing Valve Assembly, page 42.
MG0 Maintain air filter Always, if enabled Air filter exceeds user-set limit.
Maintenance due.
Service main air filter and con-
trol filter regulator. See Replace
Air Filter Element, page 31.
P5A
P5B
Pressure exceeded alarm
limits
Always, if enabled Pressure exceeded high or low
alarm limits for more than 15
seconds.
Adjust pump pressure regulator,
change tips, or adjust target set
point.
Alarm
Code Alarm Problem When Active Cause Solution