Graco 313289s Paint Sprayer User Manual


 
Repair
40 313289S
Air Controls
Remove Air Control Assembly
1. Remove shroud. See Remove Shroud, page 32.
2. Disconnect air motor air lines and system air line.
3. Remove four nuts (7) from front of air control
bracket (319).
4. Pull out assembly.
5. Follow steps in reverse order to reinstall air control
assembly.
Replace Solvent Pump Ball Valve
1. Remove shroud. See Remove Shroud, page 32.
2. Disconnect air motor air lines and system air line.
3. Remove four nuts (7) from front of air control
bracket (319).
4. Pull out assembly.
5. Remove two nuts (330) from front of air control
bracket (319).
6. Disconnect air line (332) running to ball valve
assembly (326).
7. Replace with new ball valve assembly. See Air
Controls Module (255761) Parts, page 74.
8. Follow steps in reverse order to reassemble.
Replace Solvent Air Regulator
1. Remove shroud. See Remove Shroud, page 32.
2. Disconnect air motor air lines and system air line.
3. Remove four nuts (7) from front of air control
bracket (319).
4. Pull out assembly.
5. Remove regulator nut (331), and disconnect air
lines (332, 333) running to regulator (325).
6. Remove regulator assembly and replace with new.
See Air Controls Module (255761) Parts, page 74.
7. Follow steps in reverse order to reassemble.
Replace System Air Regulator
1. Remove shroud. See Remove Shroud, page 32.
2. Disconnect air motor air lines and system air line.
3. Remove four nuts (7) from front of air control
bracket (319).
4. Pull out assembly.
5. Remove regulator nut (340) and disconnect system
air line.
6. Remove screws from quick clamps and open
clamps (342b, 342c) at hinge.
7. Remove regulator assembly (345) and replace with
new. See Air Controls Module (255761) Parts,
page 74.
8. Follow steps in reverse order to reassemble.
Replace Solenoid Inlet Air Regulator
1. Remove shroud. See Remove Shroud, page 32.
2. Disconnect air motor air lines and system air line.
3. Remove four nuts (7) from front of air control
bracket (319).
4. Pull out assembly.
5. Disconnect air line.
6. Remove gauge from block (343).
7. Remove screws from quick clamps (342a, 342b)
holding air regulator assembly (344) in place.
8. Open clamps (342a, 342b) at hinge and pull apart
from block (343).
9. Remove regulator assembly (344) and replace with
new. See Air Controls Module (255761) Parts,
page 74.
10. Follow steps in reverse order to reassemble.
11. Set new air pressure regulator to 80-85