Graco 313289s Paint Sprayer User Manual


 
Repair
34 313289S
Update Fluid Control Module (FCM)
Software
1. Remove shroud. See Remove Shroud.
2. Use software token 16A265. See Graco Control
Architecture
Module Programming manual for
instructions.
NOTE: Upgrade all modules in the system to the
software version on the token, even if you are
replacing only one or two modules. Different soft-
ware versions may not be compatible.
All data in the module may be reset to factory
default settings. Record all settings and user prefer-
ences before the upgrade, for ease of restoring
them following the upgrade.
The latest software version for each system can be
found at Tech Support at www.graco.com.
Replace Fluid Control Module (FCM)
NOTE:
The USB module does not need to be removed prior to
replacing the FCM.
1. Remove shroud. See Remove Shroud.
2. Disconnect power.
3. Remove four nuts (4); leave two nuts on left side of
panel tight. Open front panel of control box (11).
4. Remove all cables from FCM (218). Take note of
cable locations.
5. Loosen four mounting screws (235).
6. Slide FCM up and out of keyhole slots.
7. Follow steps in reverse order to install new FCM.
8. Load software. See Update Fluid Control Module
(FCM) Software.
9. Most of the system configuration is stored in the
FCM. Use the display to change the configuration to
the values in the old FCM. See XM plural-compo-
nent operation manual for instructions.
218
235
235
r_312359_313289_26