Graco 3A0868G Power Roller User Manual


 
Installation
18 3A0868G
Electrical
Power Connection (non-IS units only)
Enclose all cables routed in the spray booth and high
traffic areas in conduit to prevent damage from paint,
solvent, and traffic.
The ProMix 2KE operates with 85-250 VAC, 50/60 Hz
input power, with a maximum of 2 amp current draw.
The power supply circuit must be protected with a 15
amp maximum circuit breaker.
Not included with system:
Power supply cord compatible to your local power
configuration. Wire gauge size must be 8-14 AWG.
The input power access port is 22.4 mm (0.88 in.) in
diameter. It accepts a bulkhead strain relief fitting or
conduit.
1. Verify that electrical power at the main panel is shut
off. Open Control Box cover.
2. Connect electrical cord to the terminal block as
shown in F
IG
. 6.
3. Close the Control Box. Restore power.
4. Follow instructions in Grounding, page 19.
All electrical wiring must be completed by a qualified
electrician and comply with all local codes and
regulations.
F
IG
. 6. Control Box Electrical Connection
F
IG
. 7. Electrical Schematic
ti16391a
Ground
Neutral
Line
LINE POWER
FILTER
POWER
SUPPLY
TERMINAL
BLOCK
SWITCH
ROCKER
1A
1
2A
2
L N GRND
L GRND N
L N