Graco 3A0868G Power Roller User Manual


 
System Errors
52 3A0868G
Error Codes
Table 3: System Alarm/Advisory/Record Codes
Code Description Details
Alarm Codes - Alarm sounds, system stops, icon dis-
plays until problem is solved and alarm is cleared.
CA Communication Error 53
CAU1 USB Communication Error 53
EQU2 USB Installed when not in Standby 54
SG Gun Flush Box Error 54
SAD1
SAD2
Atomizing Air During Purge - Gun 1
Atomizing Air During Purge - Gun 2
54
SFA1
SFB1
PreMix Error - Color
PreMix Error - Catalyst
55
SHA1
SHB1
PreFill Error - Color
PreFill Error - Catalyst
55
SM MixFill Start Error 55
SN MixFill Complete Error 55
QPD1
QPD2
Potlife Error - Gun 1
Potlife Error - Gun 2
55
R1 Ratio Low Error 56
R4 Ratio High Error 57
QDA1
QDB1
Overdose A, B Dose too Short
Overdose B, A Dose too Short
57
QTA1
QTB1
Dose Time A Error
Dose Time B Error
58
QLAX
QLBX
Leak Error A
Leak Error B
58
DJA1
DJB1
Linear Sensor Error - Pump A
Linear Sensor Error - Pump B
58
DKA1
DKB1
Reed Switch Error - Pump A
Reed Switch Error - Pump B
58
P4A1
P4B1
Pressure High Error - Pump A
Pressure High Error - Pump B
58
P6A1
P6B1
Pressure Transducer Error - Pump A
Pressure Transducer Error - Pump B
58
DDA1
DDB1
Diving/Cavitation Error - Pump A
Diving/Cavitation Error - Pump B
59
EFA1
EFB1
Park Error - Pump A
Park Error - Pump B
59
DFA1
DFB1
Stall Up Error - Pump A
Stall Up Error - Pump B
59
DGA1
DGB1
Stall Down Error - Pump A
Stall Down Error - Pump B
59
DHA1
DHB1
No Stall Error - Pump A
No Stall Error - Pump B
59
Advisory Codes - No alarm, system continues operat-
ing, icon displays on active screen until cleared
MAA1 Pump A maintenance due N/A
MAB1 Pump B maintenance due N/A
MEA1 Mix valve A maintenance due N/A
MEB1 Mix valve B maintenance due N/A
MESA Solvent valve A maintenance due N/A
MESB Solvent valve B maintenance due N/A
MGA1 Fluid Filter A maintenance due N/A
MGB1 Fluid Filter B maintenance due N/A
MGP1 Air Filter maintenance due N/A
ES System defaults loaded N/A
Record Codes - No alarm, system continues operating,
no icon displays on active screen.
EL System powered on N/A
EC System setup changed N/A
EP Pump park operation completed N/A
ET System performed an autodump after
a potlife
N/A
EQU1 USB Drive connected while in Standby N/A
Table 3: System Alarm/Advisory/Record Codes
Code Description Details