Graco 3A0868G Power Roller User Manual


 
Setup Mode Details
3A0868G 45
Maintenance 1-3 (Screens 24-26)
Maintenance 1 (Screen 24) displays if is selected
on Setup Home (Screen 17). The Maintenance Screens
display actual and target maintenance timers for pumps
and solvent valves (Maintenance 1, Screen 24), dose
valves (Maintenance 2, Screen 25), and fluid filters and
air filters (Maintenance 3, Screen 26). Maintenance tim-
ers for pumps and valves are settable from 0 to
9999999. Timers for filters are settable from 0 to 9999
days.
Press to move through the three mainte-
nance screens.
Press to clear the maintenance total that is
highlighted. A verification screen appears. Use
to highlight and press on the to clear
the batch totals. No other button press will clear the
totals. Press on the to return to the active
Maintenance Screen without clearing.
Maintenance Recommendations
The following table shows recommended starting values
for maintenance. Maintenance needs will vary based on
individual applications and material differences.
F
IG
. 42. Setup Maintenance 1-3 (Screens 24-26)
Maintenance
actual and
target
Pumps
Solvent valves
Home
Maintenance 1
Maintenance 2
Maintenance 3
Air filter
Clear
Totals
Dose
valves
Fluid
filters
Days
Component
Recommended Maintenance
Frequency
Solvent Valves 1,000,000 cycles
Fluid Filter daily
Air Filter monthly
Pumps 250,000 cycles
Dose Valves 1,000,000 cycles