Basic Operation
3A0868G 33
Purging Mixed Material
There are times when you only want to purge the fluid
manifold, such as:
end of potlife
breaks in spraying that exceed the potlife
overnight shutdown or end of shift
before servicing the fluid manifold assembly, hose
or gun.
1. Press on Run Mix Spray (Screen 2) or
from any screen to put the system in Standby.
2. Trigger the gun to relieve pressure.
3. If you are using a high pressure gun, engage the
trigger lock. Remove spray tip and clean tip sepa-
rately.
4. If using an electrostatic gun shut off the electrostat-
ics before flushing the gun.
5. Set the solvent supply pressure regulator at a pres-
sure high enough to completely purge the system in
a reasonable amount of time but low enough to
avoid splashing or an injection injury. Generally, a
setting of 100 psi (0.7 MPa, 7 bar) is sufficient.
6. If using a gun flush box, place the gun into the box
and close the lid.
7. Press on Run Mix Spray (Screen 2). The
purge sequence automatically starts.
If the gun flush box is not used, trig-
ger the gun into a grounded metal
pail until the purge sequence is com-
plete.
When done purging, the system automatically
switches to Standby mode.
8. If the system is not completely clean, repeat step 6.
NOTE: If necessary, adjust purge sequence times
so only one cycle is required.
9. Trigger the gun to relieve pressure. Engage trigger
lock.
10. If spray tip was removed, reinstall it.
11. Adjust the solvent supply regulator back to its nor-
mal operating pressure.
NOTE: The system remains full of solvent.
NOTE: If your system uses 2 guns, you must trigger
both guns simultaneously during a purge to purge both
guns and lines. Verify that clean solvent flows from each
gun. If not, repeat purge or clear clog/blockage in sys-
tem.
Purging Fluid Supply System
Follow this procedure before:
the first time material is loaded into equipment
servicing
shutting down equipment for an extended period of
time
putting equipment into storage
1. Press on Run Mix Spray (Screen 2) or
from any screen to put the system in Standby.
2. Trigger the gun to relieve pressure.
3. If you are using a high pressure gun, engage the
trigger lock. Remove spray tip and clean tip sepa-
rately.
4. If using an electrostatic gun, shut off the electrostat-
ics before flushing the gun.
5. Disconnect the component A and B fluid supplies at
the pump inlets, and connect solvent supply lines.
6. Adjust the solvent fluid supply pressure. Use the
lowest possible pressure to avoid splashing.
7. Remove the Control Box cover to access the sole-
noid valves. See F
IG