Graco 3A0868G Power Roller User Manual


 
Setup Mode Details
3A0868G 49
F
IG
. 50. A/B Control Range with Properly Sized
Restrictor
B Pressure
Too High
B Pressure
Too Low
C
o
n
t
r
o
l
R
a
n
g
e
A Pressure B Pressure
F
IG
. 51. A/B Control Range with Too Large a
Restrictor
B Pressure
Too High
B Pressure
Too Low
C
o
n
t
r
o
l
R
a
n
g
e
(
t
o
o
s
m
a
l
l
)
A Pressure B Pressure
NOTE: If the restrictor is too small, it may be
necessary to supply more differential pressure
than is available in your system.
F
IG
. 52. Schematic Diagram of Dynamic Dosing Operation
Component A (continuous flow) Proportioned Material
To Static
Mixer
Component B (pulsed injection)
Table 2: Dynamic Dosing Troubleshooting Guide
(for complete system troubleshooting, see Table 3 beginning on page 52)
Error Message Solution
Ratio Low Error (R1) Increase A pressure or decrease B pressure.
Use a smaller restrictor.
Ratio High Error (R4) Increase B pressure.
Clean restrictor or use a larger size.
Verify B valve is opening properly.