Graco 3A0868G Power Roller User Manual


 
Setup Mode Details
44 3A0868G
Recipe 1-1 (Screen 28)
Note about Settings of 0: If Ratio is set to 0, the sys-
tem will dispense the A material only. If Potlife Time is
set to 0, the potlife alarm is disabled.
Recipe 1-1 (Screen 28) displays if is selected on
Setup Home (Screen 17). The Recipe Screens allow the
user to set up the basic recipe. Recipe 1-1 (Screen 28)
includes the ratio of Material A to Material B (0 to 30),
ratio tolerance (1 to 99 percent), and potlife time (0 to
240 minutes).
Recipe 1-2 (Screen 29)
Note about Settings of 0: If a Flush time is set to 0,
that valve will not flush.
Recipe 1-2 (Screen 29) includes timers for first, second
and third flush:
First flush: Always an A side purge, using the A side
flush material from the A purge valve.
Second flush: Always a B side purge, using the B
side flush material from the B purge valve.
Third flush: User settable to run the A purge valve or
the B purge valve for any required additional flush,
as selected in the dropdown for the third flush
source (A or B).
All flush times are settable from 0 to 240 seconds. Set
flush time to 0 seconds to skip a flush in the sequence.
For example, to skip the first flush (A side purge), enter
0 seconds. The system goes immediately to the second
flush, followed by the third flush as user defined.
e of 0 seconds to skip a flush. For example, enter 0 seconds for A, 30 seconds for B, 30 seconds for the third flush time, and select A for the third flush source. The system will skip the first A flush, go directly to the second flush with the B purge valve for 30 seconds followed by the third fl ush with the A purge valve for 30 seconds.
Press to highlight the desired field and press
to select. Press to move between dig-
its. Press to change a digit. Press when
field is correct.
Press to toggle between the Recipe
screens.
Press to return to Setup Home (Screen 17).
F
IG
. 39. Configure 3 (Screen 20) and Configure 4
(Screen 21)
F
IG
. 40. Recipe 1-1 (Screen 28)
USB log
language
Password
Date
format
Date
Time
Home
Distance
units
Volume
units
Pressure
units
Configure 3
Configure 4
Backlight
timer
Recipe
number
Ratio
Home
Potlife
timer
Ratio
tolerance
F
IG
. 41. Recipe 1-2 (Screen 29)
Recipe
number
Third flush
source
Second
flush time
(B purge)
First flush time
(A purge)
Third flush time
(uses material
set in next field)
Home