Graco 3A0868G Power Roller User Manual


 
Setup Mode Details
3A0868G 43
Configure 1-4 (Screens 18-21)
Configure 1 (Screen 18) displays if is selected on
Setup Home (Screen 17). This screen allows users to
set up the system type (pump or meter) and number of
guns (1 or 2).
NOTE: If 1 gun is selected, users can enable a gun flush
box (=yes; X=no). The gun flush box option is avail-
able only for 1-gun systems.
For all pump systems, the type of dosing is dynamic,
and the number of colors is 1. See Dynamic DosingDy-
namic Dosing, page 48, for more information.
Press to highlight the desired field. Press
to display the dropdown menu for that field.
Press to choose from the menu options and
to set. Press to move to the next field.
Press to move through Configure 2 (Screen
19), Configure 3 (Screen 20), and Configure 4
(Screen 21).
NOTE: If you change system type (pump to meter) or
number of guns, a verification screen appears. Use
to highlight and press on the to make the
change, or on the to return to Configure 1 (Screen
18) without making a change. If a change is made, the
system locks so that you cannot spray or mix. Power
down and power back up again to clear the lock and put
the new settings into effect. The lock ensures that the
selection was intended, and prevents the user from
attempting to operate with incorrect settings.
Configure 2 (Screen 19) allows users to set for each gun
the hose length (0.1 to 45.7 m, 0.3 to 150 ft) and hose
diameter (0.1 to 1 inch). The system uses this informa-
tion to calculate pot life volume. The pot life volume tells
the system how much material must be moved to trigger
a reset of the pot life timer. It also tells the system the
volume needed to fill during a load sequence.
Users also can configure the flow rate region and the air
flow switch. The flow rate region (High/Low) determines
the sensitivity of the overdose alarm:
Select the High setting if your flow rate is 250
cc/min or higher. The High setting has a 100cc over-
dose volume.
Select the Low setting if your flow rate is less
than 250 cc/min. The Low setting has a 50 cc over-
dose volume.
The air flow switch can be disabled here for airless
applications. Select to enable or to disable.
A change in any of these fields will trigger the lock. See
NOTE in previous paragraph.
Configure 3 (Screen 20) allows users to set preferred
language (for optional USB Module), date format, date,
time, password (0000 to 9999), and number of minutes
(0 to 99) of inactivity required before the backlight turns
off. Configure 4 (Screen 21) allows users to set pre-
ferred units for distance, volume, and pressure.
F
IG
. 36. Configure 1 (Screen 18)
Home
System
type
Number
of guns
Gun flush
box
F
IG
. 37. Confirm Change of System Type
F
IG
. 38. Configure 2 (Screen 19)
Gun 1
hose
length
Gun 1
hose
diameter
Gun 2
hose
length
Gun 2
hose
diameter
Home
Flow rate
region
Air
flow
switch